Rev. colomb. ortop. traumatol ; 34(3): 223-230, 2020. ilus.
Article in Spanish | LILACS, COLNAL | ID: biblio-1378151

ABSTRACT

Introducción Existe una diferencia estadísticamente significativa del 1.2% en la tasa de revisión a 15 años a favor de cerámica- polietileno altamente entrecruzado (CP), demostrada en el registro nacional de artroplastia australiano. Nuestro objetivo es evaluar la costo-efectividad entre los pares: cerámica-polietileno altamente entrecruzado (CP) y metal- polietileno altamente entrecruzado (MP) para el pagador en Colombia. Materiales y métodos Se construyó un árbol de decisiones TreeAge Pro® comparando CP vs MP desde la perspectiva del Sistema de Salud Colombiano (SSC). Los parámetros se tomaron de la mejor evidencia disponible, para la efectividad se realizó una revisión sistemática de la literatura y para los costos se usaron tarifas del mercado local. Se determinó la relación de costo-efectividad incremental, asumiendo un horizonte temporal de 15 años y aplicando una tasa de descuento del 5% para costos y efectividad. La incertidumbre fue controlada por un análisis de sensibilidad determinístico y probabilístico. Resultados Para el SSC, con un umbral de 1 PIB per cápita por año de vida ganado ajustado por calidad (AVAC), en adultos llevados a RTC el uso de CP no es costo-efectiva, dado que la efectividad es similar (MP:11,32 AVAC vs CP: 11,36 AVAC) y el costo es tres veces mayor (MP $ 861.826 COP vs CP $ 2.298.090 COP). El análisis de sensibilidad determinístico demuestra que la variable más importante en el resultado es el costo de la cerámica. Discusión Para el SSC el uso rutinario de cabezas de cerámica en RTC no es una estrategia costo-efectiva.


Background There is a statistically significant difference of 1.2% in the revision rate in a 15 year follow in favour of the use of ceramic on highly cross-linked polyethylene (CP) recently described in the Australian National Joint Registry. The purpose of this study is to compare the cost-effectiveness of CP implants and metal-on-highly cross-linked polyethylene (MP) implants in patients undergoing total hip replacement (THR). Materials and methods A TreeAge Pro® decision tree was constructed in order to determine cost-effectiveness between two bearing surfaces: CP or MP from the perspective of the Colombian Health Care System (CHCS). The model parameters where taken from the best available evidence. For the effectiveness, a systematic review of the literature was performed, and costs were taken from local market rates. The incremental cost-effectiveness ratio was determined assuming a time horizon of 15 years, and a discount rate of 5% was used for costs and effectiveness. Cost-effectiveness uncertainty was controlled with deterministic and probabilistic sensitivity analysis. Results For the CHCS, with a 1PIB per capita threshold adjusted per QALY in adults undergoing (THR), the use of a CP implant is not cost-effective, given that the effectiveness is similar (11.32 QALY for MP vs 11.36 QALY for CP), and the cost is three times higher (MP $ 861.826 COP vs CP $ 2.298.090 COP). The deterministic sensitivity analysis showed that the most important variable in the results is the ceramic cost. Discussion for the CHCS the routine use of ceramic-highly cross-linked polyethylene bearing surface in a THR is not a cost-effective strategy.


Subject(s)
Humans , Arthroplasty, Replacement, Hip , Polyethylene , Ceramics , Cost-Benefit Analysis , Metals
2.
Rev. colomb. ortop. traumatol ; 33(3-4): 115-122, 2019. ilus.
Article in Spanish | LILACS, COLNAL | ID: biblio-1377966

ABSTRACT

Introduccion La tendencia creciente de uso de implantes no cementados y el desarrollo de tecnologías que buscan restablecer la anatomía y función articular con una mayor preservación ósea, ha incrementado el uso de vástagos cortos en el remplazo total de cadera (RTC). El objetivo de este estudio es describir resultados funcionales, restauración radiológica de la anatomía, tasa de complicaciones y reintervención de pacientes sometidos a RTC usando vástagos femorales cortos de fijación cervico metafisiaria con apoyo en cortical lateral. Materiales y Métodos Estudio descriptivo prospectivo, donde se incluyeron 45 caderas en pacientes con artrosis de cadera de cualquier etiología. El seguimiento fue de 18 meses. Las variables de desenlace evaluadas fueron: 1. Integración del implante, 2. Complicaciones dependientes del implante femoral, 3. Subsidencia y 4. Reintervención. Se evaluó adicionalmente el resultado funcional con escala WOMAC. Resultados Durante el periodo comprendido entre diciembre de 2011 a julio 2017, encontramos una mejoría en estado funcional en el 97% (n:44) de los pacientes, no hubo reintervenciones. Discusión En el 100% de los casos se encontró osteointegración del implante y los resultados son comparables con los reportes de la literatura. Consideramos que el uso de vástagos cortos en el Reemplazo total de Cadera es un procedimiento seguro, con buenos resultados, teniendo la ventaja de una adecuada integración ósea del implante y garantizar un mejor stock óseo en una próxima cirugía.


Background The growing trend in the use of non-cemented implants and the development of technologies that attempt to restore the anatomy and joint function with greater bone preservation has increased the use of short stems in the total hip replacement (THR). The objective of this study is to describe functional results, radiological restoration of the anatomy, complication and revision rate of patients undergoing THR using short femoral stems with metaphyseal cervical fixation with lateral cortical support. Materials and Methods A prospective descriptive study was performed that included 45 hips of patients with hip osteoarthritis of any origin. The follow-up was 18 months. The outcome variables evaluated were: 1. Integration of the implant, 2. Complications dependent on the femoral implant, 3. Subsidence, and 4. Re-intervention. The functional result was additionally evaluated using the Western Ontario and McMaster Universities Arthritis Index (WOMAC). Results During the period from December 2011 to July 2017, an improvement was observed in functional status in 97% (n: 44) of patients, with no reoperations. Discussion Bone integration of the implant was observed in 100% of the cases, making the results comparable with the reports in the literature. It is believed that the use of short stems in total hip replacement is a safe procedure, with good outcomes. It also has the advantage of an adequate bone integration of the implant, and guaranteeing a better bone stock in the next surgery.


Subject(s)
Humans , Arthroplasty, Replacement, Hip , Prostheses and Implants , Femur Neck
3.
Acta ortop. mex ; 31(6): 292-299, nov.-dic. 2017. tab, graf
Article in Spanish | LILACS | ID: biblio-949783

ABSTRACT

Resumen: Introducción: Uno de los puntos más críticos en la planeación de las artroplastías de cadera es la selección del implante, puesto que su supervivencia impacta significativamente la salud de los pacientes. Sin embargo, hasta el momento no se ha definido cuál es la supervivencia ideal que debe demostrar un implante para ser seleccionado. El objetivo de este consenso es definir los estándares mínimos de desempeño para la selección de prótesis en reemplazo primario convencional de cadera. Material y métodos: El consenso se realizó mediante la metodología de «grupo nominal¼. Esto incluyó: 1. Revisión de la evidencia disponible y definición de los temas a evaluar, 2. Reunión para la votación y discusión y 3. Análisis estadístico cuantitativo con medianas (M) y rangos intercuartílicos (RIC) y cualitativo con proporciones de los resultados obtenidos para generar recomendaciones. Resultados: La fuente primaria de información para la selección de prótesis (M: 8; RIC: 7-9) y de elección en caso de evidencia contradictoria (M: 8; RIC: 7-9) o limitada en la literatura (M: 7; RIC: 4.75-825) son los registros nacionales. El mínimo seguimiento aceptable es 10 años (M: 9; RIC: 8-9) y el mínimo de supervivencia aceptable es 90% a 10 años (M: 8; RIC: 5-8.5). Discusión: De acuerdo con estos resultados, el consenso de expertos propone que la selección del implante en el reemplazo articular primario convencional de cadera se realice con base en la información publicada en los registros nacionales y que dicha prótesis tenga un seguimiento mínimo de 10 años y demuestre una supervivencia mínima de 90%.


Abstract: Background: One of the most critical points in the planning of hip replacement surgeries is the selection of the implant, since its survival significantly impacts the patients' health. However, the ideal survival time that an implant must prove to be selected has not been defined. The objective of this consensus is to define minimum performance standards for the selection of conventional primary hip replacement prosthesis. Material and methods: The consensus was carried out using the methodology of 'nominal group'. This included: 1. A review of the available evidence and the issues to be evaluated, 2. Meeting for the vote and discussion, 3. Quantitative statistical analysis with median (M) and interquartile range (IQR) and qualitative one with proportions of the results to generate recommendations. Results: The primary source of information for prosthesis selection (M: 8; IQR: 7-9), choice in the event of conflicting evidence (M: 8; IQR: 7-9), or limited evidence in the literature (M: 7; IQR: 4.75-825) should be national registries. The minimum acceptable follow-up is 10 years (M: 9; IQR: 8-9) and the minimum acceptable survival is 90% at 10 years (M: 8; IQR: 5-8.5). Discussion: According to these results, the consensus of experts proposed that the selection of the implant for conventional primary hip replacement must be based on the information published in the national registries and that the prosthesis must have a minimum follow-up of 10 years and show a minimum survival of 90%.


Subject(s)
Humans , Arthroplasty, Replacement, Hip , Hip Prosthesis , Prosthesis Design , Reoperation , Prosthesis Failure , Follow-Up Studies , Consensus
4.
Article in Spanish | LILACS, BINACIS | ID: lil-789902

ABSTRACT

Introducción: El objetivo de este estudio retrospectivo fue observar el comportamiento de un tallo modular de fijación proximal y anclaje distal en revisiones de cadera con defectos femorales II y IIIA (Paprosky), evaluando la estabilidad protésica y articular, la restauración del offset y la diferencia de longitud. Materiales y Métodos: Se analizaron 22 revisiones de reemplazos totales de cadera. Doce mujeres y 10 hombres (edad promedio 62.38 años). El seguimiento promedio fue de 62 meses. El tallo femoral utilizado fue S-ROM® (Depuy, Johnson & Johnson). Los defectos óseos femorales fueron 15 de tipo II y 7 de tipo IIIA de Paprosky. Para la evaluación clínica se utilizó el puntaje de cadera de Harris. En las radiografías, se analizó el comportamiento del tallo, su integración, la diferencia de longitud y el offset femoral, y se consideró correcta una diferencia <5 mm. Resultados: El offset fue restaurado en 16 (72,3%) casos y la longitud de miembros se restauró en 15 (68,2%). Hubo un solo hundimiento del tallo, y de acuerdo con la clasificación de Engh, se observaron 17 (77,27%) uniones óseas. Se produjeron siete (31,8%) complicaciones, dos luxaciones que requirieron revisión, cuatro fracturas intraoperatorias y una paresia de ciático poplíteo externo. Conclusiones: Este tallo impresiona ser una alternativa válida para resolver un problema complejo. Por su versatilidad, permite resolver mecánicamente el defecto óseo, devuelve la longitud al miembro y el offset a la articulación, con un índice de complicaciones aceptables.


Background: The purpose of this retrospective analysis was to observe the outcomes of a modular hip system in revision total hip arthroplasty with Paprosky types II and IIIA femoral bone defects, evaluating their performance, offset restoration and leg length discrepancy correction. Methods: Twenty-two revision total hip arthroplasties were analyzed in 12 women and 10 men (average age 62.38 years). The average follow-up was 62 months. Femoral stems S-ROM® (Depuy, Johnson & Johnson) were used. Paprosky femoral bone deficit were 15 types II and 7 IIIA. Clinical evaluation was performed using the Harris Hip Score, while Engh lassification was used for stem fixation. Offset restoration, leg length discrepancy (a difference <5 mm was considered correct) and hip stability were evaluated radiographically. Results: Offset was properly restored in 16 (72.3%) cases and the leg length was matched in 15 (68.2%). There was a single stem subsidence and according to Engh classification, proximal bone ingrowth fixation was obtained in 17 (77.27%) patients. There were 7 (31.8%) complications: two dislocations that required revision, four intraoperative fractures and a lateral popliteal nerve paresis. Conclusions: S-ROM® modular system seems to be a valid alternative to solve a complex problem. Its versatility allows to optimize hip stability, leg length equalization and offset restoration in revision total hip arthroplasty, showing an acceptable complication rate.


Subject(s)
Adult , Middle Aged , Arthroplasty, Replacement, Hip/adverse effects , Leg Length Inequality , Retrospective Studies , Follow-Up Studies , Reoperation
5.
Rev. Asoc. Argent. Ortop. Traumatol ; 76(2): 146-151, jun. 2011. ilus, tab
Article in Spanish | LILACS | ID: lil-600245

ABSTRACT

Introducción: El reemplazo total de cadera bilateral en un tiempo genera controversia en la bibliografía. Quienes están a favor argumentan que se reducen los tiempos quirúrgicos y anestésicos, la estadía hospitalaria, la rehabilitación y los costos económicos. Quienes se oponen aducen que está asociado a mayor índice de complicaciones, como trombosis venosa profunda, tromboembolia pulmonar, osificaciones heterotópicas y resultados funcionales subóptimos. Materiales y métodos: Se realizaron 40 reemplazos totales de cadera bilaterales en un tiempo, en 20 pacientes: 16 varones (80 por ciento) y 4 (20 por ciento) mujeres, con un promedio de edad de 56 años y un seguimiento promedio de 25 meses; el ASA promedio fue de 2. Se utilizaron prótesis no cementadas e híbridas. Resultados: Todos los pacientes se encontraron satisfechos con los resultados en el último control. El hip score promedio fue de 90,4 puntos. El tiempo de cirugía promedio fue de 186 minutos, requiriendo 27 minutos menos para los reemplazos no cementados. Todos los pacientes deambularon a las 72 horas de la operación y 17 pacientes debieron recibir transfusiones. El seguimiento promedio fue de 25 meses (rango 8 a 72 meses). Conclusiones: El reemplazo total de cadera bilateral en un tiempo, en la presente serie, mostró ser un procedimiento seguro. Depende de una adecuada selección del paciente, del correcto estudio de sus comorbilidades, además de la posición en decúbito dorsal y la utilización de prótesis no cementadas. Mostró disminuir los costos económicos y obtener una recuperación funcional más rápida que los realizados en dos tiempos, sin aumentar los índices de complicaciones.


Background: The literature on bilateral simultaneous total hip replacement (BTHR) is controversial. Those who agree with the procedure, contend that it reduces the amount of anesthetic, surgical time and hospital stay, the rehabilitation is faster and economic costs are lower. Opponents argue that it is associated with a higher rate of complications, such as deep vein thrombosis, pulmonary embolism, and heterotopic ossification leading to subop-timal functional outcomes.Methods: 40 BTHR were performed in 20 patients. 16 males (80%) and 4 (20%) females, average age: 56 years, and average follow up: 25 months, the average ASA was 2. Uncemented and hybrid prostheses were used. Results: All patients were satisfied with the results at the last control. The average Hip Score was 90.4 points. The average surgery time was 186 minutes for hybrid replacements, requiring 27 minutes less for uncemented implants. All patients walked at 72 hs POP, and 17 required blood transfusions. The median follow-up was 25 months (range: 8-72 months). Conclusions: In our series the BTHR proved to be a safe procedure after an appropriate patient selection, the correct study of their co-morbidities, supine position for surgery, and cementless prosthesis. The economic costs were reduced, and the functional recovery was faster than in the two-stage bilateral THR, without increasing the complication rate.


Subject(s)
Middle Aged , Hip Joint/surgery , Arthroplasty, Replacement, Hip/methods , Comorbidity , Follow-Up Studies , Patient Satisfaction , Patient Selection , Postoperative Complications , Retrospective Studies , Risk Factors , Time Factors